ATS Designers Guide 11
1.2 User Interface
The user interface – manipulators, readers – is the only system element the user has
direct contact with. It serves to inform the user of the state of the system, allow taking
system control actions, and serves as a basic programming and maintenance channel for
the installing technician and programmer. The Advisor MASTER system offers a whole
range of RAS equipment, differing in appearance and functionality. It can also be made
compatible with equipment by other manufacturers, through the use of the ATS1170
Wiegand interface.
The unique function offered by the ATS system is alarm system control – arming and
disarming the alarm – through the readers and user cards. This is enabled by integrating
the access control and alarm systems.
Each piece of RAS equipment can be used in the ATS system to unidirectionally control
the access control passage. To ease the use of manipulators to control the doors, they
have been equipped with appropriate hardware features – lock control output, door
access switch (RTE) input – and software functions, through which access control on the
control panel level can be provided for budget sensitive applications.
RAS stations characteristics:
Alarm system control – Arming and disarming the system is the basic function of each RAS unit. Beyond
that, LCD-equipped units can serve to validate alarms, suspend zones, browse the event
log etc. – the common maintenance tasks in an alarm system. It is required that there is
at least one LCD manipulator present in the system configured for alarm system
maintenance.
Basic programming interface – LCD manipulators are the basic programming interface for the system. It is
strongly recommended that at least one LCD manipulator in the system is configured for
programming the system.
State LEDs The RAS stations are equipped with LED diodes, which serve to display the state of the
system. Commonly there are 3 diodes:
Green – Power On
Orange – unit failure
Red – alert.;
In some equipment the red diode also displays the state of the RAS station area. In that
case the system state is encoded as follows:
Alert – The diode is pulsing;
Arming– The diode is lit continuously, if any of the station’s zones is armed
Disarmed–The diode is not lit, provided all zones of the RAS station are disarmed.
System bus– The RAS units are connected via the RS485 bus – addressed and queried (polled) by the
control panel. Each unit except ATS1190/92 is capable of terminating the bus.
Output– Dedicated for controlling the execution units for control panel managed access control.
Input– Dedicated for the exit button in access control.
Access control integration– Each unit can be used as an access control interface in control panel as well as
locally in the access control DGP. Access control carried out in the control panel can use
the dedicated inputs and outputs of the RAS station.
Additional equipment such as the ATS1340 – door connection box – as well as software
programming capabilities – blocking the door alarm zone etc., is typical for access
control.
CCTV integration – Control of a multiplexer – a DVMR/DTX recorder is accessible only through LCD
manipulators.