ATS Designers Guide 43
Remote star
In case the need arises to design a remote star configuration too extensive to allow the
use of the ATS1740 amplifier modules (the total of the branch length is more than 6km),
the fibre-optic modules can be used – Drawing 3-14.
1
T
5
. . . .
ATS1740
15
. . . .
ATS1740
3
. . . .
ATS1740
T
T
T
T
T
T
T
Galvanic insulation
1.5kV
1000m
1000m
1000m
ATS1743
ATS1743*
L
TT
Galvanic
insulation
* -Additional power supply necessary
Drawing 3-14 Remote star configuration.
3.2 Local bus
3.2.1 ATS1250/60 access control DGP
3.2.1.1 RS485
The ATS1250/60 access control DGP local bus has the same parameters as the system
bus and is therefore subjected to the same design rules. All system bus specifications –
the wiring, device addressing, topology etc. – hold their power when designing the access
control DGP local bus.
Using the local bus, up to 16 readers and 15 DGP modules can be connected to the
access control DGP. DGP expansions are used in the ATS1260 elevator controller only.
3.2.1.2 Wiegand/Clock&Data Interface
The ATS1250/60 controllers are equipped with 4 interfaces for direct connections with
Wiegand and Clock&Data readers. The interface automatically recognizes type of
connected reader.
The maximum distance from the reader to the controller is 70m – the wiring should be
done using UTP/FTP cat. 5 cables. Connection D0 and D1 within single pair of wires
should be avoided. It is recommended to pair the D0 and D1 signals with the ground. The