ATS2000/3000/4000/4500 Manager’s Guide
To inhibit/uninhibit RASs/DGPs
1. Access menu option 16.
The display shows:
2. Enter 1 for RAS or 2 for DGP, and press [ENTER].
If RAS is selected, the display shows any RAS’s that are inhibited:
If DGP is selected, the display shows any DGP’s that are inhibited:
3. Enter the RAS/DGP number to be inhibited.
If the number entered is not recorded, it is added and displayed.
If the number entered is already recorded, it is deleted and removed from the display
or
Press [ENTER] to return to the menu.
Inhibiting a DGP does NOT inhibit the alarm zones on that DGP, but does disable
DGP off-line/on-line reporting (TAMPER switch).
Inhibiting a RAS or DGP also resets any system alarm generated by the RAS or
DGP.
See also: Types of Alarms - System Alarms
17. ENABLE / DISABLE SERVICE TECHNICIAN
Use this function to enable and disable the service technician’s code. This option is to be
used when a service technician or engineer can only gain access to the installer menu
when this option is enabled by a user.
To enable/disable the service technician code
1. Access menu option 17.
The display shows:
2. Use one of the following options:
1-RAS, 2-DGP Inhibit / Uninhibit
0-Exit, Menu:
No RAS's Are Inhibited
Inhibit RAS:
No DGP's Are Inhibited
Inhibit DGP:
0-Cancel, 1-Service In
Option: