Page 102 Manager Manual for the CD72/95/15001
Message Extra Description
Aux.Power zone
The auxiliary power supply monitored via this zone has failed for
this zone.
Batt.Fault --
There has been a battery fault. The system cannot be armed as long
as there is a fault in the battery
Batt.OK --
The battery fault has been resolved
Break-in zone
There has been a break-in alarm in this zone
Cas.Tam. location
Means there has been a casing tamper. After this message the
casing is displayed (‘Panel Tamper’, ‘Zone Expander’ or ‘Remote
rr’). The tamper was in system 'Sn'. Panel tamper comprises the
tamper switch in the cabinet and the inputs ‘External tamper’ and
‘Bell tamper’
Change code user
The user has changed a user code.
Change date user
The user has changed the date.
Change time user
The user has changed the time.
CodeTam remote
A wrong code has been entered 10 times on a remote panel.
Dial.Com whole
system
The panel can no longer communicate with the dialler.
Eng. Abs --
The engineer has exited engineer mode.
Eng.Pres --
The engineer code has been entered and the panel is in engineer
mode from that moment.
Eng.Reset --
An alarm was triggered when the engineer exited engineer mode.
This alarm has been reset using the engineer code.
Eng.Res system
There has been a raid, tamper or break-in alarm in the system
necessitating an engineer reset.
Eng.Test engineer
The engineer has carried out a walk test.
Entry/Exit zone
There has been a break-in alarm in this entry/exit zone
ER by system
An engineer reset has been carried out for the system.
Exit fault --
Automatic arming failed because there was an exit fault.
Exit fault 000
Arming using upload/download resulted in an exit fault.
Exit fault action list
Arming using the action list failed because there was an exit fault.
Exit fault user
The user attempted to arm the system. This resulted in an exit fault.
Exit fault zone
Arming using the key switch in this zone resulted in an exit fault.
Fire zone
There has been a fire alarm in this zone.
Fire door zone
There has been an alarm in this zone which has been programmed
as a fire door.
Forced system
The system has had a forced disarm.
Fuse fuse
The fuse is defective.
GDReset system
The system has had an engineer reset via the GD-input (38).
Inhibit zone
This zone is inhibited. The following display indicates who inhibited
the zone. If the display shows ‘Up/Download’, the inhibit was
carried out using upload/download.
KeyArm zone
The key switch in this zone has fully armed the system.
KeyDisarm zone
The key switch in this zone has disarmed the system.
KeyDoor zone
The key switch in this zone has operated the unlock.
KeyPart. zone
The key switch in this zone has partially armed the system.
KeyRst zone
There was an alarm while the system was disarmed. This alarm has
been reset using the key switch in this zone.
Line fault whole
system
The dialler detects that the PTT line is not working correctly.