Schematic overview of the CD 72/95/150 option list
The flowchart overleaf gives an overview of all the options in the CD72 and CD95/150 alarm systems. It also
shows the keypad keys you need to press in order to arrive at the options.
Options listed in grey are only available for the CD95/150 alarm system.
The symbols used to represent the keys are as follows:
ü Accept X Reject Move forwards Move backwards
OPTION LIST FOR THE CD72/95/150
There are nine possible menu options in this system. Depending on how the system has been programmed
by the installer, your code may not give you access to all of the options. If you want to access more options
than you currently are able to, contact your installer.
The menu options let you carry out the following operations:
Menu option Function
1. Arm Menu There are eight possible sub-options:
Normal Set
Set the alarm.
Partguard
Set the alarm with automatic inhibiting of
zones. These zones are programmed by
the installer.
Set (no buzzer)
Set the system with no exit time.
Forced Arm
Set the system will all ‘Open Zone(s)’
inhibited.
Delay AutoArm
Delay timeslot.
AADly Until [time]
Set time for automatic arming.
AutoArm Ignore
Ignore next automatic arming.
Set Manager Slot
Enter a holiday period.
Previous Menu
Return to previous menu.
2. Inhibit Inhibit open zones.
3. Walk/Bell/Ch Test Test the zones, internal/external bells & switch chime on/off.
4. Light Menu Switch on, inhibit, and associate buzzer with the lights.
5. Unlock Unlock a door.
6. E.Log/Time/Date Detailed list of all events in the system, changes current time and
date.
7. Change codes Change your own code or, if programmed, all codes and user names.
8. Operator Log List of most recent events in the system to which you have access,
these events are cleared the next time the system is armed.
9. Finished? Exit the system.