Page 42 Manager Manual for CD72/95/15003
ARMING WITH OPEN ZONES AS A STANDARD USER
When arming the system, you may get the message ‘Open Zone(s)’ along with a list of the zones in the
premises that have not yet been closed. Attempt first to close these zones. If this is not possible, you can
inhibit these zones during arming. Because you can use both security areas, you can also select one security
area to use.
Only use this inhibiting option when absolutely necessary as any inhibiting of zones will reduce the security
level of your system. If the system is disarmed, all the inhibited zones will appear in the display after ‘In
Operator Log’.
Although you can exclude an open zone when a tamper alarm has been triggered (identified by the letter ‘T’
in front of the open zone listed), you will not be able to arm the system until the tamper alarm has been
rectified.
1. Go to the keypad. The current status of the areas is shown
in the display.
1 2
2. Press the 0 key and then enter your code.
Enter Code
0 + code
A ‘*’ appears in the display for every key you press. Use the
0 key to cancel an incorrect entry
Enter Code ****
3. An underscore appears alternately under ‘1’ and ‘2’. Enter
the number of the area required.
1 2
1 2 3
4 5 7
7 8 9
0
1
Normal Set
The system begins arming, ...
Normal Set á
... but there are still open zones, which the system indicates
here.
Open Zone(s)
In this case, zone 3 in the hall is not closed. This can be
inhibited.
003 Hall
4. After entering áá the message ‘Inhibit Zone_’ appears to
indicate what zones you want to inhibit.
Now enter ‘3’ to inhibit zone 3
1 2 3
4 5 7
7 8 9
0
áá + 3
Inhibit Zone 3
When zone 3 is inhibited this message appears.
If ‘Inhib. Not Poss.’ appears in the display, you cannot
inhibit the zone entered
003 Hall
Inhibited
The system begins to arm.
If the system still cannot arm, the message ‘Open Zones’
appears again. In that case repeat the above actions.
=1= 2