Aritech ADVISOR CD 7203 Manual de usuario Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 108
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
Manager Manual for CD72/95/15003 Page 39
PARTIAL ARMING (PARTGUARD) OF A SPLIT SYSTEM
(as an extra user or manager, with and without exit time)
Partguard means arming with automatic inhibiting of a number of zones. These automatically inhibited zones
are programmed in advance by the installer.
This is used, for example, to arm the ground floor when you go to bed. Because the system is split, you can
select one or more areas from the available security areas.
1. Go to the keypad. This shows the status of the areas.
Areas 1 and 2 are disarmed.
1 2
2. Press the 0 key and then enter your code. A ‘*’ appears in the
display for every key you press. Use the 0 key to cancel an
incorrect entry and to restart a new entry of the code.
Enter Code
0 + code
Enter Code ****
3. An underscore appears alternately under ‘1’ and ‘2’. Enter
the number of the area required.
1 2
To arm area 1, therefore, enter ‘1’.
1 2 3
4 5 7
7 8 9
0
1
This is the first menu option from which you can make a
selection for area 1.
Arm Menu
4. Press the accept key to use the option list.
1 2 3
4 5 7
7 8 9
0
üü
5. Use the ââkey to go to ‘Partguard’.
Normal Set
1 2 3
4 5 7
7 8 9
0
ââ
6. Press the accept key üüto partially arm area 1.
Partguard
Area 1 begins the arming procedure.
1 2 3
4 5 7
7 8 9
0
üü
The arrow appears to indicate that it is now possible to
inhibit zones using the áákey. See ‘Arming with open
zones as an extra user or manager’ on page 22.
Partguard
If area 1 cannot partially arm, the text ‘Open Zones’
appears. Close the zones displayed or go to ‘Arming with
open zones as an extra user or manager’ on page 22.
Whether the beeper starts depends on how the system was
programmed by the installer.
If you hear the beeper, this means that the exit time is
starting. If, however, you do not hear the beeper, no exit
time is programmed and you must not be in the secured
area.
Beeeep
Continued on next page....
Technical Manuals Online! - http://www.tech-man.com
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 107 108

Comentarios a estos manuales

Sin comentarios